How many sockets off a spur

Web4 jan. 2024 · Can I spur off a socket for an outside light? There is no need for a fused spur/fcu if you are just spurring one or two double sockets off the ring. If you take the new light from the lighting circuit, you don’t need a fused spur. Feed and neutral will get you to the light. See also Best outdoor motion sensor Flood lights. Web18 mei 2008 · If you were to connect an FCU directly to the ring circuit, you can then connect both your sockets to the load terminals of the FCU. This is an easy safe way to do it, but it will limit the total power for the new sockets to 13A, but that will be plenty for a TV and a DVD player.

Can you use a switched spur as a light switch? - KnowledgeBurrow

Web19 nov. 2024 · you can have maximum one double socket as a normal spur but if you are going from socket to FCU fused at 13 amp from there you can add as many sockets as you wish as all the sockets and cable will be protected by the fuse so no chance of overloading the cable the fuse will blow first. Web22 jan. 2014 · Woody said: The maximum load you can run from a spur is 13A (Approx 3kW). If the socket is spurred dircetly form the ring (with no fused connection unit) then … hunter chemicals nsw pty ltd https://soulfitfoods.com

Taking a spur off a spur: can it be done safely? DIYnot Forums

WebThis week I’ve seen a unfused spur from a socket on the ring to a single socket (in 2.5 6262Y) – then from the single socket to a FCU in 1.5 6242Y for the boiler. Is it OK to … Web11 sep. 2024 · How many Spurs can I take off a socket? You can have one unfused spur per socket-outlet on a ring main or one fused spur per socket-outlet, you can have as … WebYou can’t spur off a socket twice, so how many Spurs can you throw off a socket? Only one spur per socket is permitted, and the number of spurs must not exceed that … hunter chemicals melbourne

Wiring multiple sockets on fused spur - DIYnot Forums

Category:How many plug sockets can you spur off? (2024)

Tags:How many sockets off a spur

How many sockets off a spur

Spur a new twin socket from existing socket - MyBuilder

WebYou can have one unfused spur per socket-outlet on a ring main or one fused spur per socket-outlet, you can have as many sockets as you like off of a fused spur. Share … Web18 okt. 2024 · How much load can you put on a spur? The maximum load you can run from a spur is 13A (Approx 3kW).If the sockets are fed from a fused connection unit (and …

How many sockets off a spur

Did you know?

WebIf it’s a pretty standard setup; 16amp MCB, 2.5mm cable, 15 sockets (more about this below) and you want to plug in and run 10 tumble driers all at the same time, then the … WebFor most domestic socket and lighting circuits, this should suffice. Is it possible to run a fused spur from a spur? So, even if it’s fused, a spur of a spur is never allowed. I’ll …

Web10 mrt. 2024 · Pete999. There is no restriction on the number of sockets that can be supplied from a fused spur as the cable cannot be overloaded, however on a practical basis the use of the sockets would need to be limited to a total of 13A total to avoid the fuse … Web26 jul. 2024 · How many sockets can you spur off a ring? One off each spur unfused. if you come off the ring into a fused spur you can have as many sockets after that as you …

Web14 feb. 2024 · How Many Sockets Can Be on a Spur? Only one spur can be connected to a single socket. Are plug sockets without switches illegal UK? 2 Answers from MyBuilder Electricians Un-switched sockets are not illegal and are used for powering appliances that should not be switched off externally like Fridge/freezers and so on. WebHow to wire a spur electrical socket UK Spend Time, Save Money, DIY 40.7K subscribers Subscribe 2.2K Share 239K views 4 years ago In this video I show how I wire in a spur …

WebHow many sockets can be on a radial spur? Non-fused spur can only have one twin socket or one fixed appliance and a fused spur can have as many sockets as you requirebut care should be taken to ensure that the total load does not exceed the 13A fuse within the switched or unswitched-fused connection unit. hunter chemicals sdsWeb10 feb. 2024 · you can have maximum one double socket as a normal spur but if you are going from socket to FCU fused at 13 amp from there you can add as many sockets as … hunter chemistry style fifa 18WebThere can only be one spur per socket The total number of spurs must not exceed the total number of sockets already on the radial or ring circuit The spur must be connected to the existing circuit using the same size and … hunter chelsea refined original bootWeb15 feb. 2024 · Only one socket outlet can be connected to a spur. (This can be a single or double outlet). Connecting a further outlet is NOT permitted, as this could overload the … marty weiss hollywoodWebThe spur socket only has a single cable, with the connections to Live, Neutral and Earth. This is exactly the same as connecting at the end of a radial circuit. The other end of the … marty weiss flying eagle financialWebIf the socket is on a ring, Your only allowed 1 spur if sockets a spur you cant. You have to fuse it down to 13amp through a FCU first. ie fan would have to come off load of FCU … hunter chelsea wellington bootsWeb21 jan. 2024 · If you are unsure what appliances consume more power, try the socket overload calculator on this page as a guide. Here are the recommendations by the ESC … hunter chemistry style